Single component polyurea for non-stick applications 30-50 mils
 RS-510 is a single component, MCU coating designed for high film thickness applications which require maximum abrasion resistance and hardness with the additional benefit of non-stick properties. RS-510 is ideally suited for the inside of concrete drums to prevent buildup. RS-510’s specialized formulation allows resistance to the abrasive environment as well as preventing adhesion to the concrete. This coating forms a flexible, high solids film over prepared steel, aluminum, non-ferrous metal, galvanized metal, concrete, and previously existing coatings. - Non-stick surface to prevent concrete buildup
- High surface tolerance with excellent adhesion
- Excellent abrasion & chemical resistance
| - Applies at 30-50 mils
- Superior flexibility & no cracking at high DFT
- Can be applied by brush or airless spray
|  | Substrates | Types of Applications | | - Carbon Steel
- Galvanized Metal & Aluminum
- Ferrous and Non-Ferrous Metal
- Previously Existing Concrete
| - Ready Mix concrete drum
- Batch Plants
- Chutes
- Injection mold liner
| |  Color: Finish: Volume Solids: VOC: | Green Semi-gloss 63.0% ± 2.0 < 2.8 lb/gal (< 340 g/L) | Number of Coats: Flash Point: Application Temp: Dry Heat Resistance: Shelf life: | 1 or more 110°F Tag closed cup 20°F - 160°F (-7°C - 71°C) 400°F (204°C) continuous 12 Months (40°F - 100°F) - Store indoors | @ 13 mils wet - 50% Relative Humidity (RH) | | 40°F (4°C) | 77°F (25°C) | 95°F (35°C) | 120°F (49°C) | 160°F (71°C) | Touch | 1 hr
| 45 minutes
| 20 minutes
| 10 minutes
| 5 minutes
| | Recoat | 45 minutes | 15 minutes
| 15 minutes
| 8 minutes
| 5 minutes
| | Cure | 10 days
| 7 days
| 5 days
| 4 days
| 2 days | - For faster dry times, add R-CAT.
- Dry time is a function of temperature, humidity and coating thickness.
 - General Surface Preparation
Surface must be clean, dry, and in sound condition. Remove all oil, dust, grease, dirt, loose rust and contaminates to ensure proper adhesion. Prepare surfaces using SSPC-SP1 Solvent Cleaning and SSPC-SP12/NACE No. 5 Low Pressure Water Cleaning methods to remove surface contamination. Supplement weathered galvanized surface preparation with ISO 8501-1 St 2 (SSPC-SP 2 and 3) hand and power tool cleaning to remove excessive corrosion and impart surface profile on bare metal. Spot prime clean bare metal with a Rivera Coatings recommended primer. Supplement new galvanized surface cleaning with mechanical abrasion to impart surface profile and support mechanical adhesion. Use SSPC-SP1 solvent cleaning to remove contaminants prior to employing surface preparation methods. Blast Clean surfaces for immersion or severe service projects to SSPC- SP10/NACE No. 2 Near White Metal finish. Prepare surfaces for non-immersion or atmospheric service projects to SSPC-SP6/NACE No. 3 Commercial Blast Clean finish. For minimum surface preparation use conscientious power tool cleaning methods in accordance with SSPC-SP3. Blast cleaning methods should produce a surface profile of 1.0 - 2.0 mils (25-51 microns). | - Previously Existing Coatings
Prepare surfaces using SSPC-SP12/NACE No. 5 Low Pressure Water Cleaning methods to remove surface contamination. Supplement SSPC-SP 12 LPWC with SSPC-SP1 Solvent Cleaning and ISO 8501 St 2 (SSPC-SP2 and 3) Hand and Power Tool clean areas of corrosion and loose or flaking paint (feather edges of sound, existing paint back to a firm edge). OR prepare surfaces using SSPC-SP 12/Nace 5.0 High or Ultra High Pressure waterjetting to WJ. Spot prime clean, bare metal with a Rivera Coatings recommended primer. Sand glossy surfaces to provide profile. Apply a test sample to a small area to determine coating compatibility. Concrete which is not bonded to the surface well must be removed by cleaning with a strong detergent. Refer to ASTM D4258. Form release agents, hardeners, etc. must be removed by abrasive blasting, shot blasting, mechanical scarification, or suitable chemical means. Follow general surface preparation and solvent cleaning per SSPC-SP1. Scuff sand to abrade surface. Test adhesion. Self-Priming. | The surface to be coated must be dry, clean, dull, and free from dirt, grease, oil, rust, mill scale, salts or any other surface contaminants that interfere with adhesion. Ensure welds, repair areas, joints, and surface defects exposed by surface preparation are properly cleaned and treated prior to coating application. Areas of oxidation after surface preparation and prior to coating application, should be prepared to specified standard consult the referenced standards, SSPC-PA1 and your Rivera Coatings Representative for additional information or recommendations. - For guidance in methods of surface preparation and for visual standards, refer to STEEL STRUCTURES PAINTING MANUAL, VOL 2, SYSTEMS AND SPECIFICATIONS, published by Steel Structures Painting Council (SSPC).
|  - RS-510 can be applied by brush and airless spray (one grade only). Follow proper mixing instructions before applying.
Material temperature must be 5° F (3°C) above the dew point before opening and agitating. Power mix thoroughly prior to application. Do not keep under constant agitation. Apply a 3 - 6 oz solvent float over material to prevent moisture intrusion and cover pail. Brush: Medium Natural Fiber Pump Ratio: 60:1 Pressure: 2400 - 3000 psi (170 - 207 Bar) Hose: 1/4” to 3/8” ID Tip Size: 0.015 - 0.021 Filter Size: 60 mesh (250 μm) | Thinning is not required. MEK, MIBK, Xylene, a 50:50 blend of Xylene and MEK or MIBK, or acetone. Do not add unauthorized Rivera Coatings solvents to a Rivera Coatings product. Temperature: 10° - 160° F (-7° - 71° C) This temperature range should be achieved for ambient, surface and material temperature. Substrate must be visibly dry and free from contaminants. Relative Humidity: 6% - 99% Store off the ground in a dry, protected area in temperature between 40 - 100°F (4 - 38°C). MCU containers must be kept sealed when not in use. Use a solvent fl oat to reseal partial containers. |  Packaging: Weight per Gallon: Shelf life: Flash point: DOT Hazard Class DOT Packaging Group: DOT Label: DOT Shipping name: UN/NA Number: | 3 and 5 gallon pails 8.5 ± 0.5 lb 12 months from date of shipment when stored under specified conditions 110°F Tag closed cup 3 III FLAMMABLE LIQUID UN 1263 Paint 1263 |  - Consult the MSDS before use.
- Apply Material with adequate air exchange and ventilation.
- All application personnel must use respirators rated for organic vapors, or if in confined spaces, wear fresh air respirators or fresh air hoods.
- Wear protective clothing, gloves and eye protection.
- Breathing fumes or contact with the skin may cause allergic reactions.
 - No warranty of current accuracy is hereby given or implied. The statements made herein are based on our research or the others.
- Rivera Coatings assumes no responsibility for coverage, performance or injuries resulting from use or handling. Liability, if any, shall be limited to product replacement.
- In no event shall Rivera Coatings be liable for consequential or incidental damages.
- Published product information is subject to change without notice.
- Contact Rivera Coatings for current product information.
|